Technical support

Select the product:

Luxpanel™

luxpanel soporte

Troubleshooting

Reversed connection
Check the polarity of the cable and power supply, connect them correctly.

 

Lack of power
Connect the product to a higher power source (W).

 

Incorrect voltage
Connect the product to the power supply indicated on the label of the panel or cable.

 

Excessive sagging
Fix or replace LED illuminator.

 

Forced power cord
Fix or replace LED illuminator.

Excess cable
Reduce the length of the cable to the power supply.

 

Inadequate voltage
Connect the product to the proper power source as indicated on the panel or cable label.

Excessive sagging
Fix or replace LED illuminator

One side of the panel is not connected
Connect all wires coming from the panel to the power supply(s).

The panel has the transparent protector
Remove the transparent protector from the panel.

 

The panel has been vinylized directly
Use a vinyl backing, do not vinyl the panel directly.

Too little separation between graphic and panel
Separate the graphic more from the panel.

 

Inadequate diffuser
Increase the separation between the panel and the support or change the support for a thicker one.

Electrical connection

Depending on model.

This product is designed to be connected to a low voltage DC source of 5V, 12V or 24V depending on the model, as indicated on the cable label or the label on the back of the product.

luxpanel soporte

Uses

No. The product is designed for indoor use due to its IPx4 protection (to achieve a better watertightness you must close it in a space that guarantees the required IP).

Yes, as long as the separation between the graphic and the panel is taken into account.

The panel is designed for indirect lighting or backlighting.

It can be drilled with a 3-point bit anywhere on its surface except in the profile area. Any other manipulation of the product will void the warranty.

Not directly. The panel is a light source, a vinyl polycarbonate can be used and placed on top of the panel.

Dotpanel

dotpanel soporte

Troubleshooting

Reversed connection
Check the polarity of the cable and power supply, connect them correctly.

 

Lack of power
Connect the product to a higher power source (W).

 

Incorrect voltage
Connect the product to the power supply indicated on the label of the panel or cable.

 

Excessive sagging
Fix or replace LED illuminator.

 

Forced power cord
Fix or replace LED illuminator.

Excess cable
Reduce the length of the cable to the power supply.

 

Inadequate voltage
Connect the product to the proper power source as indicated on the panel or cable label.

Excessive sagging
Fix or replace LED illuminator

One side of the panel is not connected
Connect all wires coming from the panel to the power supply(s).

The panel has the transparent protector
Remove the transparent protector from the panel.

 

The panel has been vinylized directly
Use a vinyl backing, do not vinyl the panel directly.

Too little separation between graphic and panel
Separate the graphic more from the panel.

 

Inadequate diffuser
Increase the separation between the panel and the support or change the support for a thicker one.

Electrical connection

Depending on model.

This product is designed to be connected to a low voltage DC source of 5V, 12V or 24V depending on the model, as indicated on the cable label or the label on the back of the product.

dotpanel soporte

Uses

No. The product is designed for indoor use due to its IPx4 protection (to achieve a better watertightness you must close it in a space that guarantees the required IP).

Yes, as long as the separation between the graphic and the panel is taken into account.

The panel is designed for indirect lighting or backlighting.

It can be drilled with a 3-point bit anywhere on its surface except in the profile area. Any other manipulation of the product will void the warranty.

Not directly. The panel is a light source, a vinyl polycarbonate can be used and placed on top of the panel.

Frontline

frontline-supp-2

Troubleshooting

Reversed connection
Check the polarity of the cable and the power supply, connect them correctly. Disconnect the power supply from the mains for 3 minutes and connect the product correctly.

 

230V connection
The product has been damaged by a higher load than indicated. The product must be replaced with a new one and connected to a 24V DC source.

 

Short circuit
Check if there is a short circuit along the 24V line and correct the connections.

 

Short circuit upstream of the power input. Only the power supply is affected. In this case, check the user’s guide and the power supply specifications.

 

Short circuit downstream of the power input. Actilum products may suffer internal damage that worsens their performance. Disconnect the power supply from the mains for 3 minutes, check the wiring and connect the product correctly.

 

Flashing
The power supply is at the limit of its actual power because its capacity does not match the expected capacity. Replace with a higher power supply.

 

Lack of power: connect the product to a higher power source (W).

 

Check that the power supply is receiving power.

 

Inadequate voltage: connect the product to the power supply as indicated on the PCB connectors.

Do not drill holes in the back of the box to avoid light leakage.

 

Make sure the inside of the box is white.

 

Use reflective material on the inside of the box.

 

Check that the power supply is not amperage limited and that the voltage at the product connectors is 24V.

 

Excess cable
Reduce the cable length to the power supply, if not possible, increase the supply voltage to a maximum of 24.8V.

 

Inadequate voltage
Connect the product to the proper power supply.

 

Some segments do not light up
Verify that the polarity along the line has not been reversed in any of the segments. Check the connection at the connectors.

Over voltage
Verify that the voltage is 24.8V max.

 

Defective element
Contact Actilum and if necessary process your warranty RMA.

 

Poor dissipation between element and profile
Fix the product on an aluminum base to dissipate heat.

Solder on the PCB, without resting on a metal profile and at a minimum of 400ºC.

 

Use the appropriate tool.

 

Send the product to Actilum for repair.

Contact Actilum to make use of the warranty through the RMA procedure. Use the form at the bottom of this page.

Check the distance between Frontline and the graph.

 

Check the distance between elements.

Measures

The distance between elements is ~1 mm.

frontline-supp-2
Electrical connection

Max. units connected in series according to CE and UL standards.

 

Frontline M9
CE:16
UL: 11

 

Frontline M9+
CE:10
UL: 6

If you purchased the power supply from Actilum, refer to the custom assembly document for detailed instructions. If you cannot find it contact Actilum for assistance. Otherwise, consult your supplier.

Depending on the model, a dimmer module can be added or the input voltage can be reduced to <24V.

This product is designed to be connected to a 24V low voltage DC source.

Uses

No. The product is designed for indoor use due to its IPx4 protection (to achieve a better watertightness you must close it in a space that guarantees the required IP).

The product is designed for indirect lighting or backlighting.

It can be cut only in the cut areas as indicated in the image. It can be soldered only at the points indicated in the image. Solder on the PCB, without resting on a metal profile and at a minimum of 400ºC. Any other manipulation of the product will void the warranty.

 

Parallel

parallel soporte

Troubleshooting

Reversed connection
Check the polarity of the cable and the power supply, connect them correctly. Disconnect the power supply from the mains for 3 minutes and connect the product correctly.

 

230V connection
The product has been damaged by a higher load than indicated. The product must be replaced with a new one and connected to a 24V DC source.

 

Short circuit
Check if there is a short circuit along the 24V line and correct the connections.

 

Short circuit upstream of the power input.
Only the power supply is affected. In this case, check the user’s guide and the power supply specifications.

 

Short circuit downstream of the power input.
Actilum products may suffer internal damage that worsens their performance. Disconnect the power supply from the mains for 3 minutes, check the wiring and connect the product correctly.

 

Flashing
The power supply is at the limit of its actual power because its capacity does not match the expected capacity. Replace with a higher power supply.

 

Lack of power: connect the product to a higher power source (W). Check that the power supply is receiving power.

 

Inadequate voltage: connect the product to the power supply as indicated on the PCB connectors.

Excess cable
Reduce the cable length to the power supply, if not possible, increase the supply voltage to a maximum of 24.8V.

 

Inadequate voltage
Connect the product to the proper power supply.

 

Some segments do not light up
Verify that the polarity along the line has not been reversed in any of the segments. Check the connection at the connectors.

Over voltage: Verify that the voltage is 24.8V max.

 

Defective element

 

Poor dissipation between element and profile: fix the product on an aluminum base to dissipate heat.

Solder on the PCB, without resting on a metal profile and at a minimum of 400ºC.

 

Use the appropriate tool.

 

Send the product to Actilum for repair following the form at the bottom of this page.

Contact Actilum to make use of the warranty through the RMA form at the bottom of this page.

Check the distance between Parallel and the graph.

 

Check the distance between elements.

Contact Actilum to make use of the warranty through the RMA form at the bottom of this page.

XL model only
Contact Actilum to make use of the warranty through the RMA form at the bottom of this page.

XL model only
Contact Actilum to make use of the warranty through the RMA form at the bottom of this page.

Measures

M and XL models
The distance between elements is ~1 mm.

 

L model
The distance between elements is ~20 mm.

 

Flex-L models
The distance between elements is ~16 mm.

If your box is only illuminated on one side, place the elements as far away as possible from the graphic to be illuminated, otherwise place the modules centered.

parallel soporte
Electrical connection

Max. units connected in series according to CE and UL standards.

 

Parallel M
Max. units connected in series Europe (CE): 10
Max. units connected in series (max. 96W) (UL): 6

 

Parallel L

RegulationParallel L1Parallel L3Parallel L5Parallel L3+Parallel L5+
CE25148106
UL259674

 

Parallel Flex L

RegulationParallel Flex L2Parallel Flex L3Parallel Flex L6Parallel Flex L2+Parallel Flex L3+Parallel Flex L6+
CE1914714105
UL161261284

 

Parallel XL
Max. units connected in series Europe (CE): 4
Max. units connected in series (UL): 4

If you purchased the power supply from Actilum, refer to the custom assembly document for detailed instructions. If you cannot find it contact Actilum for assistance. Otherwise, consult your supplier.

Depending on the model, a dimmer module can be added or the input voltage can be reduced to <24V.

This product is designed to be connected to a 24V low voltage DC source.

Uses

No. The product is designed for indoor use due to its IPx4 protection (for better sealing it must be closed in a space that guarantees the required IP).

 

For outdoor use Parallel XL IP is recommended.

The product is designed for indirect lighting or backlighting.

Parallel M
Can be cut only in the cut areas as indicated in the picture. It can be soldered only at the points indicated in the image. Solder on the PCB, without resting on a metal profile and at a minimum of 400ºC. Any other manipulation of the product will void the warranty.

parallel m corte soldadura

 

Parallel L & Flex L
No. Any other manipulation of the product will void the warranty.

 

Parallel XL
Can be cut only along the cut areas as shown in the picture. Any other manipulation of the product will void the warranty.

parallel xl cortes

Flex

flex soporte

Troubleshooting

Reversed connection
Check the polarity of the cable and the power supply,
connect them correctly.

 

Lack of power
Connect the product to a higher power source (W).

 

Incorrect voltage
Connect the product to the power supply indicated on the label on the label on the panel or cable.

Identify the damaged segment(s) and replace them. Cut in the middle of the welding pads, remove the defective segments and re-solder the segments in good condition.

 

Observe polarity when soldering.

 

Weld without resting on a metal profile and at a minimum of 400°C.

 

Use the appropriate tool.

 

Send the product to Actilum for repair.

Solder on the PCB, without resting on a metal profile and at a minimum of 400ºC.

 

Use the appropriate tool.

 

Send the product to Actilum for repair.

Excess cable
Reduce the cable length to the power supply.

 

Inadequate voltage
Connect the product to the appropriate power source
as indicated on the panel or cable label.

flex soporte

Electrical connection

Depending on the model.

This product is designed to be connected to a low voltage DC source of 5V, 12V or 24V depending on the model, as indicated on the cable label or the label on the back of the product.

Uses

No. The product is designed for indoor use due to its IPx4 protection (to achieve a better watertightness, it must be closed in a space that guarantees the required IP).

It can be cut only in the cut areas as shown in the picture. Soldering is only possible at the points indicated in the image. Solder on the PCB without resting on a metal profile and at a minimum of 400ºC. Any other manipulation of the product will void the warranty.

 

Soldering of cables

 

flex-soldadura-cables

 

 

Soldering of sections

 

flex-soldadura-tramos

 

 

Soldering of corners

flex-soldadura-esquinas

If you have a technical problem that you have not been able to solve or the product is defective you can process your warranty with this RMA form.

Before submitting your inquiry you can see our commitment to your privacy.

Responsible: Actilum RGB, S.L.

Purpose of the collection and processing of personal data: to manage the request you make in this contact form.

Rights: you may exercise your rights of access, rectification, limitation and deletion of data in info@actilum.com, as well as the right to file a complaint with a supervisory authority.

Additional information: in our privacy policy you will find additional information about the collection and use of your personal information. Including information on access, retention, rectification, deletion, security and other topics.

Warranty processing
RMA

Before submitting your inquiry you can see our commitment to your privacy.

Responsible: Actilum RGB, S.L.

Purpose of the collection and processing of personal data: to manage the request you make in this contact form.

Rights: you may exercise your rights of access, rectification, limitation and deletion of data in info@actilum.com, as well as the right to file a complaint with a supervisory authority.

Additional information: in our privacy policy you will find additional information about the collection and use of your personal information. Including information on access, retention, rectification, deletion, security and other topics.

Led’s create together

Mándanos tu currículum




Antes de enviar tu consulta puedes ver nuestro compromiso con tu privacidad

Responsable: Actilum RGB, S.L.

Finalidad de la recogida y tratamiento de los datos personales: gestionar la solicitud que realizas en este formulario de contacto.

Derechos: podrás ejercer tus derechos de acceso, rectificación, limitación y suprimir los datos en info@actilum.com, así como el derecho a presentar una reclamación ante una autoridad de control.

Información adicional: en nuestra política de privacidad encontrarás información adicional sobre la recopilación y el uso de su información personal. Incluida información sobre acceso, conservación, rectificación, eliminación, seguridad y otros temas.

Contact a technician

Before submitting your inquiry you can see our commitment to your privacy.

Responsible: Actilum RGB, S.L.

Purpose of the collection and processing of personal data: to manage the request you make in this contact form.

Rights: you may exercise your rights of access, rectification, limitation and deletion of data in info@actilum.com, as well as the right to file a complaint with a supervisory authority.

Additional information: in our privacy policy you will find additional information about the collection and use of your personal information. Including information on access, retention, rectification, deletion, security and other topics.

Contact

Before submitting your inquiry you can see our commitment to your privacy.

Responsible: Actilum RGB, S.L.

Purpose of the collection and processing of personal data: to manage the request you make in this contact form.

Rights: you may exercise your rights of access, rectification, limitation and deletion of data in info@actilum.com, as well as the right to file a complaint with a supervisory authority.

Additional information: in our privacy policy you will find additional information about the collection and use of your personal information. Including information on access, retention, rectification, deletion, security and other topics.

Scan the code
Privacy Overview
Actilum™

This website uses cookies so that we can provide you with the best user experience possible. Cookie information is stored in your browser and performs functions such as recognising you when you return to our website and helping our team to understand which sections of the website you find most interesting and useful.

Strictly Necessary Cookies

Strictly Necessary Cookie should be enabled at all times so that we can save your preferences for cookie settings.

Analytics

This website uses Google Analytics to collect anonymous information such as the number of visitors to the site, and the most popular pages.

Keeping this cookie enabled helps us to improve our website.